Load Cells PDF Print E-mail

BiSS tension-compression load cells are compact in design and are easily mounted on to the actuators, crossheads, platens and other test fixtures. The shear web load cells are relatively insensitive to side loads. These load cells are characterized by excellent linearity and seamless tension-compression response with virtual absence of hysterisis. BiSS load cells include circuitry for auto-calibration against internal shunt reference, thus obviating the need for on-site calibration during installation. These load cells are precision machined from high strength steel and the sensitive element is wire-cut and instrumented with Transducer Class strain gauges from Micro Measurements, USA, along with bonded resistor networks for bridge balance and temperature compensation. Two-step curing virtually eliminates potential process-related residual strains.          LoadCells        

 Standard features

  • 350 Ohm bridge resistance
  • Shear web design
  • Optional backing plate
  • Relatively insensitive to side loads
  • Precision machined
  • Auto calibrated

 

 LoadCells          Load Cells
                                                                 

Specifications

 Model No

 Capacity kN

 A

 B

 C

 D

 E

 F

 G

 Pitch circle

 Mounting  bolts

 Bi-06-101

 2

 70

 21

 49

 24

 7.5

 M10 x 1.5

 45

 48

 8

 Bi-06-102

 5

 105

 32

 66

 31

 8.5

 M16 x 2

 45

 88

 4

 Bi-06-104

 15

 120

 50

 70

 35

 11

 M27 x 2

 45

 104

 8

 Bi-06-105

 20

 120

 50

 70

 35

 11

 M27 x 2

 45

 104

 8

 Bi-06-106

 25

 120

 50

 70

 35

 11

 M27 x 2

 45

 104

 8

 Bi-06-107

 50

 120

 50

 70

 35

 11

 M27 x 2

 45

 104

 8

 Bi-06-108

 100

 160

 70

 92

 55

 12.5

 M27 x 2

 30

 139

 12

 Bi-06-109

 150

 170

 80

 105

 65

 12.5

 M36 x 2

 30

 146

 12

 Bi-06-110

 200

 180

 80

 140

 75

 16.2

 M36 x 2

 30

 152

 12

 Bi-06-111

 250

 180

 80

 140

 75

 16.2

 M36 x 2

 30

 152

 12

 Bi-06-112

 500

 280

 130

 100

 100

 32

 M90 x 2

 30

 260

 12

 Bi-06-113

 1000

 330

 160

 125

 125

 32

 M90 x 2

 30

 280

 12

 Bi-06-114

 2000

 330

 160

 125

 125

 32

 M90 x 2

 30

 280

 12

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 Details Specification
 Static Error Band ± 0.06% of Full scale
 Non linearity ± 0.1% of Full scale
 Hysterisis ± 0.02% of Full scale
 Non repeatability ± 0.02% of rated output
 Creep in 20 min ± 0.025%
 Side load sensitivity ± 0.08%
 Eccentric load sensitivity ± 0.06%
 Rated output 2.0 ±0.5% mv/V
 Excitation voltage 10V nominal, 15V Max
 Bridge resistance 350 Ohms
 Zero Balance ± 0.5% of rated output
 Insulation resistance 5000 Mega ohms
 Safe overload 150% of capacity
 Connector Mill connector
 Calibration Compression & Tension
 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Note: Dimensions subject to minor variations based on specific ratings.
         All dimensions are in mm
         All holes equidistant on the pitch circle
         Metric threading

We rejuvenate obsolete or abandoned systems with state-of-the-art digital controls and user-friendly MS-Windows compatible  application software