Fracture Mechanics Clevis Grips PDF Print E-mail

Bi-05-2XX fracture mechanics clevis grips are designed for static and dynamic testing of compact tension specimen in accordance with relevant ASTM standard practices. Clevises made of Nimonic material can be used at temperatures upto 10000 C, while EN24 clevises are used for room temperature applications. The fracture toughness tests such as KIc, JIc and CTOD conducted using these clevises are in accordance with ASTM E1820 and E647.

Standard features

 • Rugged
 • Temperature resistant
 • Compatible
 • In accordance with ASTM E1820 and E647      
 • Available in different sizes

 Clevis Clevis
 Clevis Grips

  Room temperature clevis grips

 Model no Specimen width (mm)Pin diameter(mm)  Weight(kg)Stud size 
 Bi-05-200 6.356.3   1 M27X2 
 Bi-05-201 12.7 6.3  1M27X2
 Bi-05-20112.7 12.7  1 M27X2 
 Bi-05-20225.4 12.7  2 M27X2 
 Bi-05-204 50.8 25.4  8 M50X2 
 Grip Dimensions (mm)
 A BC D E 
 7020  6.4 Dia 456.6 
 70 20 6.4Dia 45  13.2
 70 25 12.7Dia 45 13.2 
 99 39 13.2 Dia 68 26.6
 125 70 26.4Dia 116 53 
  

  High temperature Clevis grips

 Model no Specimen width (mm) Pin diameter(mm) Weight(kg) Stud sizeGrips dimensions (mm) 
 Bi-05-25112.7  12.7 1  M27 X 2  A B C  D E
 Dia 45 13.2  25  12.7 70
 Bi-05-252 25.412.7  2M27 X 2 Dia 68 26.6 39 13.2 99

Note: Dimensions subject to minor variations based on specific ratings.

We rejuvenate obsolete or abandoned systems with state-of-the-art digital controls and user-friendly MS-Windows compatible  application software